Overview:
Intelligent temperature and humidity incubator controller is designed for incubation industry to develop the intelligent microcomputer control system, using the latest microelectronic technology and new components. Adopt imported microcomputer chip, strong anti-interference ability, high working stability temperature measurement of high precision, wide temperature range; Choose high-performance humidity sensors, high precision, temperature compensation performance, effective guarantee product performance is stable and reliable. Humanized design, color screen display mode respectively show that the incubator temperature, humidity, set the temperature, humidity, setting eggs hatch time, number of days. At the same time, chicken, duck, goose, pigeon, chicken, custom six incubation model users are free to choose.
 
Main Technical Factors:
1. Range of temperature display: 0 ~ 99 ℃
2.Precision of temperature measurement: ± 0.1 ℃
3.Range of cleaning display: 0 ~ 99% RH
4.Precision of humidity control: ± 3% RH
5.Output channels: 7 channels (main heater, backup heater, over temperature (ventilation), turn left, turn right, humidification, dehumidification)
6.Output current: 10A for both main and backup heater, while 5A for others
7.Number of turns: maximum is 999
8.Turn period: adjustable between 0 and 999 minutes. (Default is 90 minutes)
9. Duration of turning: adjustable between 0 and 999 seconds. (Default is 180 seconds)
10. Air refreshing period: adjustable between 0 and 999 minutes. (Default is 120 minutes)
11. Duration of air refreshing: adjustable between 0 and 999 seconds. (Default is 15 seconds)
12. Length of measurement line: about 1.5 meters
 
Main Technical Factors
1.Working voltage: AC 180V ~ 240V; Frequency 50Hz
2.Relative humidity: less than 85%
3.Environment temperature: -20 ℃ ~ 70 ℃
 
Package:
1 pcs intelligent controller
Temperature and humidity sensor (2 pcs)
English manual
Display screen, buttons and parameter Settings
1. Main display button operation instructions
The 4 buttons on the right of the main screen are:SET, UP, DOWN, MODE.
In normal status ,short press “SET” button ,controller enter correct temperature setting.
Long press the “SET”button for more than 3 seconds (long press), instrument into the ventilation, calibration, parameter settings, etc.
In settings, press the “SET” button (short press) to enter the next parameter setting.
(1)   UP
a.  In normal status, press and hold “UP” button (long press) for manual turn egg function;
b.  In normal status, press the “UP” button (short press) to adjust the parameter value, and press the “UP” button to adjust the parameter value continuously.
(2)   DOWN
a. In normal status ,short press “DOWN” button can handle alarm funtion.
b.  In normal status, press the “DOWN” button (short press) to adjust the parameter value, and press the “DOWN” button to adjust the parameter value continuously.
(3)   MODE
In normal status,long press “MODE” button for 3 seconds or more, can be adjusted in sequence mode: custom, chicken, duck and goose, dove, pheasant.
(4)   Combination key
aIn normal status, pressing “SET” and “UP” button  more than 3 seconds and controller will enter temperature and humidity setting.
b. In normal status, pressing the  “UP ” and  “DOWN ” button for 5 seconds to reset all the parameters to the default.
c.  In normal status, press and hold the “MODE” button and the reduction key for more than 3 seconds (long press), count the number of eggs cleared, and the number of days to hatch is reset to 1.
d.  In normal operation, hold both the “SET” and “DOWN” button for more than 3 seconds (long press), and the instrument enters the protection function parameter setting.
e.  In normal operation, hold the “SET” and “MODE”button for more than 3 seconds (long press), and the instrument goes into the hatching days and the turn over time parameters setting.
Note: in the set state, set the parameters flashing display, when more than 10 seconds do not press the button, the system will automatically exit the set state. Previously modified parameters are automatically saved.
2.  In normal operation, click “SET” key (short press), the meter enters the base temperature and humidity parameter setting. (After the system is out of the factory, the user simply sets the reference parameter and the interval parameters are adjusted automatically with the reference parameters.)
No.
Parameter name
Parameter ID
Setting range
Default value
1
Reference temperature setting
PP (P3)
0-99.9℃
37.8
2
Reference humidity setting
HH (H2)
0-99%
60%
Note: the above reference parameters can be adjusted only in custom mode.
3.  In normal operation, press the “SET” and “UP” button for more than 3 seconds (long press). Before the system is out of the factory, the parameters of the interval have been set up, and the non professionals should not adjust.
No.
Parameter name
Parameter ID
                  Setting range
Default value
1
     Tempreature for alarm if over
P1
0-99.9℃
38.6
2
Tempreature for starting fan if over
P2
0-99.9℃
38.0
3
Tempreature for stopping main heater
P3
0-99.9℃
37.8
4
Tempreature for starting main heater
P4
0-99.9℃
37.6
5
Tempreature for starting backup heater
P5
0-99.9℃
37.5
6
Tempreature for alarm if lower
P6
0-99.9℃
37.0
7
Humidity for alarm if over
H1
0-99%
80%
8
Humidity for stopping wet
H2
0-99%
65%
9
Humidity for starting wet
H3
0-99%
60%
10
Humidity for alarm if lower
H4
0-99%
40%
Note: the above range parameters can only be adjusted in the user-defined mode.
4.  In normal operation, hold the “SET” and “MODE”button for more than 3 seconds (long press), and the instrument goes into the hatching days and the turn over time parameters setting.
No.
Parameter name
Parameter ID
                  Setting range
Default value
1
Incubation days
F0
1-99 (days)
1 (day) default first days
2
Egg turning period
F1
0-999 minutes
90minutes
3
Egg turning duration
F2
0-999 seconds
180 seconds
5.  In normal operation, press the “SET”button for more than 3 seconds (long press), and the meter enters the ventilation, calibration, parameter setting and so on.
No.
Parameter name
Parameter ID
               Setting range
Default value
1
Ventilation cycle
F3
0-999 minutes
120minutes
2
Ventilation time
F4
0-999秒
0-999 seconds
15 seconds
3
Tempreature  calibration
F5
Adjust according to the thermometer
4
Humidity calibration
F6
Adjust according to the humidometer
5
Egg turning times
F7
Adjust according to the humidometer
6
                              The main heating fuzzy control pulse width
F8
0-10
5
Remark : for the parameter F3、F4,only can adjust in the custom model .
6. In normal operation, hold the “SET” and the “DOWN” button for more than 3 seconds (long press), and the instrument enters the protection function parameter setting.
No.
Parameter name
Parameter ID
                 Setting range
Default value
1
Fan shutdown protection function
b1
0- no, 1- yes
0
2
Water dish water shortage protection function
b2
0- no, 1- yes
0
3
High temperature reset function
b3
0- no, 1- yes
0
 
Control function part
1.  Temperature controlling related functions (TH1 is the temperature within incubator box)
(1)Over tempreature alarm: if TH1 > P1, system starts alarm, turns on the indicator lighter and starts buzzer; if TH1 < P1, system turn off the alarm function.
(2)Fan: if TH1≥ P2, system starts the fan; if TH1 < P2, system stops the fan.
(3)Main heater: if TH1≤P4, system starts the main heater; if TH1≥P3, system stops the main heater. Other temperature interval main heating according to the setting pulse width F8 fuzzy control.
(4)Backup heater: if TH1<P5, system starts the backup heater; if TH1>P5, system stops the backup heater.
(5)Lower tempreature alarm: if TH1<P6, system starts alarm, turns on the indicator lighter and starts buzzer; if TH1 > P6, system turn off the alarm function.
2. humidity controlling related functions (RH1 is the humidity within incubator box)
(1)    Over humidity alarm: if RH1>H1, system starts alarm, turns on the indicator lighter and starts buzzer; if RH1<H1, system turn off the alarm function.
Humidify function: if RH1≤H3, system starts humidifier; if RH1≥H2, system stops humidifier.
(2)    Lower humidity alarm: if RH1<H4, system starts alarm, turns on the indicator lighter and starts buzzer; if RH1>H4, system turn off the alarm function.
(3)    Dehumidification function: when humidity RH1≥ H2+ F9, start dehumidifying function; When humidity RH1 ≤ H2, turn off the dehumidification function.
 
Note: when the temperature control is in high temperature alarm, turn off the humidifying function; when the high temperature alarm function is closed, the humidifying function is resumed.
(1)Manually turn the egg: in normal working conditions, press and hold “UP” button, you can turn left turn eggs in turn, turn left, turn left, right turn egg, right turn egg stop.( In the manual turn over egg condition, turn over the egg time F2, turn to the automatic egg turning state; manual turn over eggs is not included in the number of turns.)
(2)Automatic turning eggs: according to the set turn egg cycle F1 and turn over the egg time F2 automatically turn eggs, left and right turn eggs alternately.
(3)The number of turns can be displayed by pressing the key. The parameter code F7 can be adjusted by  “UP” and  “DOWN” keys. The number of turns is counted and the data is cleared after power loss.
(4)The maximum number of turns is shown 999 times. After more than 999 times, the data is cleared and re accumulated.
(5)When the turn over egg cycle F1 is set to 0, the automatic egg turning function is cancelled.
(6)Every time the adjustment mode, turn the number of eggs cleared.
4Incubation days:
(1)Incubation days, factory default is 1, starting from the instrument power, every 24 hours, the number of days of hatching automatically add one.
(2)Incubation days can be got through querying (the parameter ID is F0). User can change it through “UP” and  “DOWN”button. The number will be saved even the system is down.
(3)The maximum number for incubation days is 99. The number will be starting from 0 again once over 99.
 ( 4 ) The number of days per hatch was reset to 1 at each adjustment mode.
5.  Ventilation function:
(1)System will start (or stop) the air refreshing fan automatically according to the air refreshing period F3 and duration F4.
(2)Note: if F3 is set to 0, system will turn off the auto air refreshing.
(3)Ventilation and overtemperature exhaust are the same output terminals.
6.  Protection function:
(1)Fan stop protection function: when working on the system, when the fan work signal can not be detected, stop heating and alarm. This function can be cancelled by the parameter code b1.
(2)Water dish water and automatic water protection functions in the power system work, detection of water dish water, stop humidification and alarm; and then immediately start the automatic replenishment function, when the detected water level reaches the set water level, delay 5 seconds to stop automatic water supply function. This function can be cancelled by the parameter code b2.
(3)High temperature reset function: when working on the system, when the temperature of the case is more than 42 degrees, all the parameters will be returned to the factory defaults and the alarm will be prompted. This function can be cancelled by the parameter code b3.
7. Remove the alarm manually
When the alarm starts, user could mute it by pressing the  “DOWN” button and switch back by pressing the button again. The alarm lighter will always on during alarm period.
8Calibration function
The tempreature and humidity sensors could be appear some deviation after long time using. At this time user could calibrate them by the accurate thermometer and humidometer. When F5 displayed, press “UP ” or “DOWN” button to calibrate the tempreature; while when F6 displayed, press “UP” or “DOWN” button to calibrate the humidity.
9Reset function
In normal operation,press “UP” and “DOWN” button for 5 seconds and then all the parameters are reset to the default values after a beep.
10Sensor error indicator
If there are problems in tempreature sensor or the sensor is not available, the tempreature display window shows EEE, and at the same time the main heater, backup heater and over tempreature fan stop working; if there are problems in humidity sensor or the sensor is not available, the humidity display window shows EE, and at the same time the humidifier stops working. There will be beep warnings no mater which sensor does not work properly.  
aliexpress nepalaliexpress nepalaliexpress nepalaliexpress nepalaliexpress nepalaliexpress nepal
Click here to Buy - Poultry Intelligent Temperature Humidity Incubator Controller Chicken Bird Incubation Equipment LED Color Display 180-220V

Comments

  1. Replies
    1. Hello Sir, We don't sell products, we take preorder from aliexpress.com and deliver it here

      Delete
  2. I want it bring me here in morang
    My phone number is 9804321662

    ReplyDelete
    Replies
    1. Hello Sir, We don't sell products, we take preorder from aliexpress.com and deliver it here

      Delete
  3. Replies
    1. Hello Sir, We don't sell products, we take preorder from aliexpress.com and deliver it here

      Delete

Post a Comment